Teledyne FLIR A615 13.1mm Lens 45° FoV Thermal Machine Vision Camera
- IP Thermography Camera
- 13.1mm Lens
- 640×480 Resolution
- 45°(H) x 34°(V) FoV
- -20°C to +2000°C Object Temp Range
- GigE Vision™ & GenICam™ Compliant
- 8 Lens Options
- GenICam compliant.
- Trigg/synchronization/GPIO.
- 16-bit 640 × 480 pixel images at 50 Hz, signal, temperature linear, and radiometric.
- Windowing mode: 640 × 240 pixels at 100 Hz or 640 × 120 pixels at 200 Hz.
- Compliant with any software that supports GenICam, including National Instruments IMAQ Vision and Stemmers Common Vision Blox.
- Open and well-described TCP/IP protocol for control and set-up.
FLIR A615 (50Hz) Thermal Imaging Camera
The FLIR A615 13.1mm Lens – thermal imaging camera offers an affordable and accurate temperature measurement for a variety of applications where network capabilities and compliance with network protocols are of importance. The FLIR A615 comes with a 13.1mm standard lens providing a 45°×34° field of view and 640×480 resolution.
The FLIR A615 – has built-in analysis, alarm functionality and independent communication technology over the standard network protocols. The FLIR A615 camera also has all the necessary features and functions to build distributed single or multi-camera solutions utilizing standard ethernet hardware and software protocols.
The FLIR A615 thermal infrared camera also has built in support to connect to industrial control equipment such as PLCs, and allows for sharing of analysis and alarm results and simple control using the Ethernet/IP and Modbus TCP field bus protocol.
FLIR A615 (50Hz) Key Features
- IP Thermography Camera
- 13.1mm Lens
- 640×480 Resolution
- 45°(H) x 34°(V) FoV
- -20°C to +2000°C Object Temp Range
- GigE Vision™ & GenICam™ Compliant
- 8 Lens Options
- GenICam compliant.
- Trigg/synchronization/GPIO.
- 16-bit 640 × 480 pixel images at 50 Hz, signal, temperature linear, and radiometric.
- Windowing mode: 640 × 240 pixels at 100 Hz or 640 × 120 pixels at 200 Hz.
- Compliant with any software that supports GenICam, including National Instruments IMAQ Vision and Stemmers Common Vision Blox.
![]() |
Medical
Infrared thermography is based on analysis of skin surface temperatures as a reflection of normal or abnormal human physiology using a high performance infrared camera.
Safety
In oil/gas production, power generation or distribution there is a need to prevent and detect fires fast and automatically. A fix mounted infrared camera can be installed discretely and almost anywhere to monitor your business.
Education
FLIR infrared cameras are being used in university laboratories where high-end academic and applied research is on-going in a wide range of disciplines.
Veterinarian
An animal’s body creates heat that fluctuates throughout the body depending on blood flow. The body’s recognition of injury and a subsequent increase in blood flow can happen even before the animal shows signs of pain, and other conditions.
Automation
For the automotive industry the ability to continuously and automatically ensure quality is of great importance. A fix mounted infrared camera can be installed almost anywhere to monitor your production process.
Manufacturing
IR cameras made by FLIR have become indispensable tools for many engineering disciplines, particularly in advanced product development.
Resolution | |
---|---|
Pixel Pitch | |
Spectral Band | |
Sensitivity/NEdT | |
Frame Rate | |
Focus | |
Detector Type | |
Radiometry | |
Object Temperature Range | |
Temperature Accuracy | |
Field of View | |
Focal Length | |
f-number | |
Dimensions (L x W x H) | |
Weight | |
Digital Inputs | |
Digital Outputs |
2 opto-isolated, 10–30 VDC, max 100 mA |
Input Voltage | |
Ethernet Connector Type | |
Ethernet Protocols |
DHCP, FTP, HTTP, ICMP, IGMP, MDNS (Bonjour), RTP, RTSP, SMB (CIFS), SMTP, SNTP, TCP, UDP, uPnP |
Operating Temperature Range | |
Shock | |
Non-Operating Temperature Range | |
Humidity |
IEC 60068-2-30/24 h 95% relative humidity 25°C to 40°C (77°F to 104°F) |